20200221: ICC FLOT1/2 kit Euroimmun (controls and MS163 absorbed)

SAMPLES:

  • 1-23) ALS patients: 207-08, 208-17, 210-16, 211-10, 211-11, 214-07, 214-08, 214-13, 214-14, 215-03, 215-09, 215-14, 215-15, 215-16, 218-22, 218-28, 210-02, 219-10, 221-03, 221-08, 222-03, 223-05, 223-10
  • 24) Positive control MS 163 (non-transfected HEK cells absorbed)
  • 25) Positive control MS 163 (FLOT1/2-transfected HEK cells absorbed)

PROCEDURE

  • Patient’s sera diluted 1/10 in PBS-Tween 0,2% (LCR 1/5) –> add 30 microl to each reaction field in the reagent tray: place the biochip slides on them and incubate for 30 min at RT
  • Rinse the biochips with a flush of PBS-Tween 0,2% and immerse them in a cuvette containing PBS-Tween 0,2% for 5 minutes.
  • Add 25 microL of the fluorescein-labelled secondary antibody (kit) in each reaction field: place the biochip slides on them and incubate for 30 min at RT
  • Rinse the biochips with a flush of PBS-Tween 0,2% and immerse them in a cuvette containing PBS-Tween 0,2% for 5 minutes.
  • Mount with the mounting medium from the kit

RESULT

All the samples were negative, including the sample MS163 HEK-absorbed… Maybe because it was diluted at 1/100. Repeat immunoabsorption at 1/20!!



Print Friendly, PDF & Email

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.