20190905: Live ICC in FLOT/FLOT2

Objectives: To test samples for positivity towards FLOT1/FLOT2 (with live ICC).

Samples: Negative control, 158, 163.

Transfection: 03/09/2019 (48h)

FLOT1/FLOT2 ICC:

  • Take 3 coverslips from the plate transfected the day before and put them in a 24-well plate
  • Patient’s sera diluted 1/100 with HEK medium –> put 2,5 microl of serum in 250 microl of medium in every well. Incubate for 1h at 37ÂșC
  • Remove medium and fix with PFA 4 % for 10 min.
  • Blocking solution: Goat serum 5% diluted in PBS (1h).
  • Primary antibody: FLOT1 1/100
  • Secondary antibodies: GAR488 + GAH 594 1/1000 (1h)
  • Vectashield mounting medium.

RESULTS: All samples seem positive, including the negative control