20180813: ICC CNTN1 in CIDP patients from Holland

Objectives: To test CIDP patients for IgG positivity towards CNTN1.

Samples: From 65 to 109.

Transfection: 9/8/18

CTN1 ICC:

  • Blocking solution: Rabbit serum diluted 1/40 in PBS.
  • Patient’s sera diluted 1/100 for IgG with rabbit serum 1/40.
  • Primary antibody: AF904 diluted 1/1000.
  • Secondary antibodies: RAG 488 + RAH 594 IgM (1/1000)
  • Vectashield mounting medium.
Patient IDResult
65-
66-
67-
68-
69-
70-
71-
72-
73-
74-
75-
76-
77-
78-
79-
80-
81-
82-
83-
84-
85-
86-
87-
88-
89-
90-
91-
92-
93-
94-
95-
96-
97-
98repeat
99+
100repeat
101-
102-
103-
104-
105-
106-
107-
108-
109-
110repeat
111-
112-
113-
114-
115-
116-
117-
118-
119-
120-
121-
122+?? repeat
123-
124-
125-
126-
127-
128-
129-
130-
131-
132-
133-
134-
CONTROL --
CONTROL ++

Results: 

  • Sample 99 is positive for IgG towards CNTN1.
  • Sample 122 has a doubtful staining (maybe it’s positive?)
  • We are going to repeat CNTN1 ICC for samples 98, 100,110 and 122